Specifications

Pump Discharge volume 10ml/min
Discharge pressure 10MPa (safety valve set pressure)
Power
DC24V AC100V , 200V , ?1
DC24V
Mortor 20W/0.8A
Pressure relief solenoid 10W/0.4A
Total 30W/1.2A
Working consistency Cartridge Grease No.000,00,0,1
Recommended grease MP0, FS2, MT1
Cartridge size 200ml , 400ml , 700ml cartridge
Weight 1.8kg (4C) , 2.8kg (7C)
Pressure relief Built-in solenoid

How to order

How to order

Directions for use

  • Use recommended greases.
  • Never use molybdenum disulfide-contained grease.
  • Use lithium greases. (Contact us for consultation when other than lithium grease is used.)
  • Do not use any greases containing substances that attack brass and rubber.
  • When refilling, take care not let foreign matter in the grease.
  • Avoid continuous operation.
  • After refilling, always press AIR BLEED push button to purge the pump of air.
  • When refilling grease in main pipe and during test operation, stick to an intermittent cycle of running for 30 seconds and resting for 90 seconds. Failure to follow this requirement will result in thermal protector being activated by a heated solenoid, leaving the solenoid de-energized without pressure built up.
  • For system planning information, Contact us.
  • * Should the pump malfunction, Contact us for immediate response with substitution.

Drawing

Hydraulic circuit drawing

Hydraulic circuit drawing

Wiring digram

Wiring digram

Dimensional drawing EGME-10T-4-2C

Dimensional drawing[EGME-10T-4-2C]

S81-SC

Dimensional drawing EGME-10T-4-7C

Dimensional drawing[EGME-10T-4-7C]

S81-SC

Dimensional drawing EGME-10T-4-4C

Dimensional drawing[EGME-10T-4-4C]

S81-SC