Specifications

Discharge volume 0.2ml/stroke
Discharge port Tube of 6mm, 4mm O.D used
Grease inlet Rc1/8
Max. working pressure 20MPa
Minimum operating pressure 2MPa
Working consistency NLGI No.000-2
Performance monitor Indicator pin (K type)
Material AP:Aluminum Die-cast
SP:Aluminum

Special Parts

Model Part Number
SPB 611785
SW-10 207611
SPC 611677
SPA-6 619780
SPS 611695
SPN 611784
SPA-4 166005

Model

Model Part Number No. of discharge ports Valve size(L)
AP-4K 205680 4 75
AP-4 205690
AP-6K 205681 6
AP-6 205691
AP-6S 205686
AP-8K 205682 8
AP-8 205692
AP-8S 205687
AP-10K 205683 10 105
AP-10 205693
AP-10S 205688
AP-12K 205684 12
AP-12 205694
AP-12S 205689

 

Model Part Number No. of discharge ports Valve size(L)
SP-4K 205530 4 60
SP-4 205540
SP-6K 205531 6
SP-6 205541
SP-6S 205536
SP-8K 205532 8 75
SP-8 205542
SP-8S 205537
SP-10K 205533 10 90
SP-10 205543
SP-10S 205538
SP-12K 205534 12 105
SP-12 205544
SP-12S 205539
S: With proximity sensor adaptor
K:With indicator pin
*L: See dimensional drawing.

Principle operation

Step 1

The grease is sent by the pump or the grease gun enters from the inlet of the block upper part. The sent grease passes along the port shown in the dark gray color, reaches the right-hand side of a piston "A", and moves piston "A" leftward. At this time, the grease on the left-hand side of a piston "A" passes along the port shown in the light gray color, and is discharged from the outlet of No. 2.

fig_1

Step 2

f piston "A" carries out a full stroke leftward, as shown to Fig. 2 by the dark gray color, the port which results in surface of a piston "B" will be connected, and the grease from a pump will move a piston "B" leftward through this port. At this time, the grease on the left-hand side of a piston "B" is discharged from the outlet of No. 7 through the port shown in the light gray color.

fig_2

Step 3

Like last time, if piston "B" carries out a full stroke leftward, as shown to Fig. 3 by the dark gray color, the port which results in right-hand side edge of piston "C" will be connect, grease will pass along this port, and a piston "C" will be moved leftward. At this time, the grease on the left-hand side of piston "C" is discharged from a No. 5 outlet through the port shown in the light gray color.

fig_3

Step 4

If piston "C" carries out a full stroke, as shown by the dark gray color among the right figure, the port which results in right-hand side edge of a piston "D" will be connected, and a piston "D" will be moved leftward. At this time, the grease on the left-hand side of a piston "D" is discharged from No. 3 outlet through the port shown in the light gray color.

fig_4

Step 5

This time, as a result of piston''s "D''"'' carrying out a full stroke, as shown by the dark gray color among the figure, the port which results in left-hand side edge of a piston "A" is connected, and a piston "A" is moved rightward. At this time, the grease on the right-hand side of piston "A" which worked as last operation grease is discharged from a No. 1 outlet through the port shown in the light gray color. Grease will be discharged by the same repetition as henceforth in order of the outlet of 8, 6, 4, 2, 7, 5, 3, and 1.

fig_5

Setting of discharge volume/ Suggestions

Setting of discharge volume

As for each discharge port, 0.2 ml/stroke grease is discharged at the time of a pump operation. If one discharge port is closed, the quantity from the closed port will be added to and discharged by the next discharge port below.

Exsample × : Plugged port will not discharge.

                 1 : Discharge will be four (4) times the normal amount.

             2, 6 : Discharge will be twice the normal amount.

example

Suggestions

1. Use only the specially designed SP fittings for discharge ports of the SP type valve.

2. When you attach the dischagre port Outlet Check Body please be sure to check whether the Clamping Ring is set correctly. Moreover, when you attach SPB plug into the grease dischagre port, please be sure to remove the  Clamping Ring, if present. If a Port Plug is attached with the Clamping Ring. set, the whole valve stops operating.

3. Use proper torque when installing AP & SP Progressive Block specialty adapters.

4. Installation will become difficult if assembly of AP & SP Progressive Blocks is begun with the middle discharge ports. Begin assemble at one end and continue to the other on each side to insure proper and more efficient assembly.

5. Use the correct washer and proper torque when installing AP & SP Progressive Block port plugs.

Drawing

Piping Layout

Necessarily match the layout in Figure 1 is an example

Piping Layout

CAUTION Do not use plug SPB for discharge port 1and 2 at any time.

At this mark, use sealing compound at the point.

At this mark, it means tightening torque (See the mark in tightening torque chart ).

Dimensional drawing[SP-4K]

Dimensional drawing[SP-4K]

Dimensional drawing[AP-6S]

Dimensional drawing[AP-6S]