Keeping Machinery running all over the World
Menu
Home » Produkte » Öl-Schmierung » Positive Displacement Injector (PDI) System for Large Machines » AMI-300S / AMI-1000S

Positive Displacement Injector(PDI) System for Large Machines

Automatic intermittent gear pump AMI-300S·AMI-1000S

Specifications

  AMI-300S AMI-1000S
Pump Discharge volume 300ml/min (50Hz)
330ml/min (60Hz)
1000ml/min (50Hz)
1100ml/min (60Hz)
Discharge pressure 2.5MPa (25kgf/cm2) 217.5psi
Mortor Power AC100V?1/1.4A
(condenser 14 µF)
AC200V?3/0.35A
AC100V?1/1.4A (50Hz)
(condenser 20 µF)
AC200V?3/0.56A (50Hz)
Output 50W Induction motor 75W Induction motor
Operation rate Max. Discharge time :3min
Min. Interval time : 3min
Working viscosity range 65?1300mm2/S (50Hz)
Reservoir capacity Standard reservoir up to 50 liters available.
Weight 4.4kg 7.1kg
Others With Pressure relief mechanism,
Motor rotary direction: Clockwise
Meca-tron controller is available for controlling purpose.
External fuse 100V/2A 200V/1A 100V/3A 200V/1A

How To Order

How To Order

Model

Model Part Number
AMI-300S-1 202033
AMI-300S-2 202034
AMI-1000S-1 202103
AMI-1000S-2 202101

Directions for use

  • Do not remove the oil strainer to keep the pump clear of foreign matter.
  • Replace or clean the suction filter at least once a year. Click here to view the service list.
  • Oil viscosity varies with oil temperature. Be sure to use oil within specified working viscosity range. Click here to view the viscosity list.
  • Do not use any special additive-contained oil, water soluble oil and solvent.
  • Periodically check the oil in the reservoir for impurities. Replace it, if necessary, with fresh oil immediately. Be sure to clean the reservoir before oil change.
  • Make sure that proper voltage and pressure are proper.
  • Do not overtighten the discharge joint.
  • Refer to the tightening torque table.
  • Low-oil viscosity versions are available. Contact us for information.
  • For system planning information, Contact us.
  • * Should the pump malfunction, Contact us for immediate response with substitution.

Drawing

Hydraulic circuit drawing

Hydraulic circuit drawing

Wiring digram

Wiring digram

Dimensional drawing [AMI-300S]

Dimensional drawing [AMI-300S]

Dimensional drawing [AMI-1000S]

Dimensional drawing [AMI-1000S]