Pumps
NICOL

The NICOL oil lubrication pump is available with two different gear versions: with a “universal” variant for the use of oils of all viscosities (10–800 mm²/s) and with a gear version specially designed for high viscosities (46–800 mm²/s).
The unit's range of performance and applications is correspondingly broad. It extends from ball bearing lubrication (including in oil/air lubrication systems) to slideway lubrication and the use of adhesive and thick oils, for example for the lubrication of slideways.
The new NICOL pump is, of course, also characterized by the proverbial LUBE quality level. The individual product inspection before delivery is just one of many components that ensure that users can rely on the unit 100 percent.
Technical data
| Pump | Discharge volume | 150ml/m 50Hz |
| Discharge Pressure | 2.0 MPa | |
| Motor | Voltage | 24V DC (+/- 10%) |
| Nominal current | 1.6 A (under full load) | |
| Switch on current | 6.6 A max | |
| Nominal output | 18W / 50Hz | |
| Operating time | Continuous operation possible | |
| Emergency Detection | Oil level switch | Contact capacity AC DC 200V; 0.5A; |
| 30W and lower | ||
| Contact type B: ON at low level | ||
| Pressure switch | Contact capacity AC 125V; 0.1A; | |
| Contact capacity DC 30V; 0.1A; | ||
| Working pressure: 1.5 MPa or more (ON) | ||
| Operating time | max. / min. | Continuous |
| Operating viscosity range | 10 - 800mm²/Sec. und 46 - 800mm²/Sec. | |
| Tank | 1.8 Liter oder 3.0 Liter | |
| Protection class | IP54 | |
| Weight | 1,8l: 2,7kg / 3,0l: 3,6kg |
Dimensions
1.8 Liter
3.0 Liter

AMO-III DS

The AMO-III DS is an automatic intermittent gear pump designed for precise oil lubrication in industrial applications. It is characterized by exact metering and reliable performance. The pump has a digital display for real-time monitoring of operating conditions and alarms (including oil level and pressure deviations), thus offering the highest level of safety.
Technical data
| Pump | Delivery rate | 150ml/m (50Hz), 180ml/m (60Hz) |
| Delivery pressure | 2.0 MPa/284 psi (safety valve setting) | |
| Motor | Voltage / current consumption | AC100V 1~ / 0,83A (50Hz) |
| AC200V 1~ / 0,41A (50Hz) | ||
| AC200V 1~ / 0,64A (60Hz) | ||
| AC200V 1~ / 0,33A (60Hz) | ||
| Output power | 20W (50Hz/60Hz) Capacitor motor | |
| Control | Timer | Setting range Timer / delivery time: 1–99 s |
| Setting range Interval time: 1–9999 min | ||
| Counting function (1–9999 cycles) | ||
| Fault signal output | Contact type: Normally open (NO) | |
| Switching capacity: AC250V, 1.5A | ||
| Fault/emergency detection | Oil level switch – switches when oil level is low | |
| Pressure switch – operation: 1.7MPa, reset: 0.9MPa | ||
| LCD display | Display: “INT” (interval) | |
| Display: “DIS” (pumping) | ||
| Display: “OIL LEVEL ERR” (low oil level) | ||
| Display: “PRESSURE ERR” (pressure error) | ||
| Application range Viscosity | 68–1800 mm²/s (50Hz) | |
| Tank volume | 1.8L, 3L (plastic) | |
| 3 L, 4 L, 6 L (metal) | ||
| Weight | 1.8 L container: 3.2 kg | |
| 3 L container: 4 kg |
Dimensions